NONMEM ADVAN4 Import¶
Import a two-compartment IV bolus model from NONMEM.
NONMEM Model¶
- ADVAN: 4 (Two-compartment)
- TRANS: 4 (CL, V1, Q, V2 parameterization)
- Parameters: CL=5.0 L/h, V1=10.0 L, Q=2.0 L/h, V2=20.0 L
- IIV: CL (30% CV), V1 (25% CV)
- Error: Proportional (15% CV)
Files¶
| File | Description |
|---|---|
| run003.ctl | NONMEM control file |
| convert.py | Python conversion |
| expected.json | Expected NeoPKPD spec |
Parameter Mapping¶
| NONMEM | NeoPKPD |
|---|---|
| THETA(1) = CL | params.CL |
| THETA(2) = V1 | params.V1 |
| THETA(3) = Q | params.Q |
| THETA(4) = V2 | params.V2 |